Products List
Organic composite Transformer Bushing
Polymeric Transformer Bushing
voltage: 35KV or below
frequency:50HZ
used:insulation and support of high-voltage incoming
Polymeric Transformer BushingThe Function and Applicable Range. The FCGW series polymeric transformer bushing is applicable for mechanical support for...
Drop Out Fuse Cutout
drop-out fuse
rated voltage:10kv
max.operating voltage:12kv
drop-out fuse techinical parameters:rated voltage:10kvmax.operating voltage:12kvrated current:100A max.stored drop out current :6.3kAmin. stored drop out current:17kAcreepage distance:> 2.6Cm/kv 1 min.wet...
Drop Out Fuse Cut
drop-out fuse parameters:
rated voltage:10kv
max.operating voltage:12kv
drop-out fuse techinical parameters:rated voltage:10kvmax.operating voltage:12kvrated current:100A max.stored drop out current :6.3kAmin. stored drop out current:17kAcreepage distance:> 2.6Cm/kv 1...
composite drop out fuse/cut out fuse
Fuse cutout parameters:
rated voltage:10kv
max.operating voltage:12kv
Fuse cutout parameters:rated voltage:10kvmax.operating voltage:12kvrated current:100A max.stored drop out current :6.3kAmin. stored drop out current:17kAcreepage distance:> 2.6Cm/kv 1 min.wet power-freqency...
Busing for tansformer
Busing for tansformer
service conditions of bushing
ambient temperature:-40oC-+40oC
elevation:1000m
pollution class: class
Busing for tansformerThe FCGW high-voltage dry-type wall bushing is applicable as mechanical support for electric insulation...
Transformer bushing
Transformer bushing
service conditions of bushing
ambient temperature:-40oC-+40oC
elevation:1000m
pollution class: class 3 o
The FCGW high-voltage dry-type wall bushing is applicable as mechanical support for electric insulation of high-voltage conductors during...
Transformer bushing
service conditions of bushing
ambient temperature:-40oC-+40oC
elevation:1000m
pollution class: class 3 or above
The FCGW high-voltage dry-type wall bushing is applicable as mechanical support for electric insulation of high-voltage conductors during high-voltage...
Silicon Rubber Insulator Transformer Bushing
service conditions of bushing
ambient temperature:-40oC-+40oC
elevation:1000m
pollution class: class 3 or above
Transformer Bushing:The FCGW high-voltage dry-type wall bushing is applicable as mechanical support for electric insulation of high-voltage conductors...
Transformer bushing
specification of transformer bushing
Ambient air temperature:-40C--+40oC
The altitude:<1000m
The creepage ratio:20mm/kV
The FCGW high-voltage dry-type wall bushing is different from other similar products in CHINA and abroad.With innovative design,the products have no...
Arrester Monitor
the Arrester Monitor can test the leakage current,and be used as a counter.
The JCQ Arrester Monitor not only can test the Leakage Current,but also can be used as a Counter.It mainly has two functionsThe specification of Arrester Counter and...